Programming | IDS X Series Training V2.3
Location Definitions
A location is an area of memory that holds a value. Each location is associated to a function that the alarm
needs to operate correctly. These locations have options, other locations or different data that can be
entered, to allow for customisation depending on the property being protected and on the monitoring
company.
1. Standard Location
A standard location is an area of memory that holds a value only.
2. Extended Location
An extended location is a location that has multiple sub-locations within it.
3. Bitmap
A bitmapped location is a location that has more than one option in it and each option needs to be
enabled or disabled depending on the requirements.
Programming Standard Locations
A standard location is an area of memory that holds a value only.
To program a standard location:
1. Enter Installer mode [#] [9] [9] [9] [9] [*] (This step is only required if you are not already in installer
mode)
2. Then press the keys that represent the location number followed by the [*] key
3. Now enter the data value that needs to be in the location followed by the [*] key
4. You can enter the next location or press the [#] key to exit Installer mode
Programming Extended Locations
Sub-location Method
The sub-location method programs each sub-location within a location individually.
Entering data in the sub-location format:
1. Enter Installer mode [#] [9][9][9][9] [*] (This step is only required if you are not already in installer mode)
2. Then press the keys that represententer the location number followed by the [*] key
3. Then press the keys that represententer the sub-location number followed by the [*] key
4. Now enter the data value that needs to be in the location followed by the [*] key
5. You can enter the next sub-location or press the [#] key to exit the location
6. You can enter the next location or press the [#] key to exit Installer mode
String Method
The string method programs all sub-locations within a location at once.
Entering data in the string format:
1. Enter the location (E.g. [1] [*] )
2. Now enter the complete string of data (E.g. [0][1] [0][2] [0][4] [0][4] [0][4] [1][0] [0]5] [0][3] [*])
3. When the [*] key is pressed at the end of the string, you will be removed out of the location and the
data saved. If there is an error you will hear 3 error beeps, and will remain in the location to re-enter
the data.

Other manuals for IDS X64

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDS X64 and is the answer not in the manual?

IDS X64 Specifications

General IconGeneral
Keypads8
Stay/Away ArmingYes
Tamper ProtectionYes
Operating SystemProprietary
Supported ProtocolsContact ID, SIA
Power Supply16.5VAC
Backup Battery12VDC 7Ah
AlertsSMS
RAMUnknown

Related product manuals