IDS X Series Training V2.3 | Default 6
63
Default 6
Location 14 Global Options
LED
Factory
Default
Default
6
Action
1
ON
ON
A user assigned to any partition may cancel the siren
2
OFF
OFF
Disable keypad trouble beep
3
OFF
OFF
Disable telephone line monitoring
4
OFF
OFF
Disable keypad beep on successful reporting to the base station
5
ON
ON
Enable keypad Fire, Medical and Panic keys
6
ON
ON
Enable the display of bypassed and stay zones when armed
7
OFF
OFF
Disable the siren delay
8
ON
OFF
Enable box tamper monitoring
9
ON
OFF
Enable siren monitoring
10
OFF
OFF
Disable bus-wired peripheral tamper monitoring
11
OFF
OFF
Disable onboard dedicated panic audible
12
ON
ON
Enable low battery monitoring
13
ON
ON
Enable low battery cut-out
14
OFF
OFF
Disable bypassing with user code***
15
OFF
OFF
Disable Dedicated Panic Zone Bypassing
16
OFF
OFF
Disable remote transmitters to cancel a panic condition
Location 46 Reporting Options
LED
Factory
Default
Default 6
Action
1
ON
ON
Tone Dialling
2
OFF
OFF
Join the Telephone Numbers Together
3
OFF
OFF
Disable Dual Reporting
4
OFF
OFF
Disable Alternate Reporting
Locations 51 54 Primary Telephone Numbers
Clears all numbers

Other manuals for IDS X64

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDS X64 and is the answer not in the manual?

IDS X64 Specifications

General IconGeneral
Keypads8
Stay/Away ArmingYes
Tamper ProtectionYes
Operating SystemProprietary
Supported ProtocolsContact ID, SIA
Power Supply16.5VAC
Backup Battery12VDC 7Ah
AlertsSMS
RAMUnknown

Related product manuals