Wireless Device Hardware setup | IDS X Series Training V2.3
7.7 Panic Zone
The dedicated panic zone is end-of-line supervised and for safety reasons,
if this resistor is not detected the system will not arm.
7.8 Telephone Connections
The line coming into the building must go directly to the alarm panel and
then onto any telephones. This will stop any attempt to disrupt
communication by taking the phone off the hook.
Wireless Device Hardware setup
Note: The import thing to remember is that when you have chosen the supervision time of 3Hrs
on the X-Series is to make sure the detectors are also set to 90min.
The correct hardware must be used as the older Duevi wireless detectors will not learn to
the integrated receiver
Duevi Outdoor Wireless Dual Head PIR - 866-DX-OPWF
Note: To learn the dual PIR to the X-Series first get both PIR heads to detect movement then press
the tamper switch when in location 260 sub-location 1 and the correct zone number has
been selected
Dip Sw
Function
Enable /Disable
Description
1
Double Pulse
Off = Disabled
When enabled the upper head must
trigger twice within 25 seconds before
an activation is sent
On = Enable
2
IR Sensitivity
Off = High
On = Low
3
AND Mode
Off = Normal
Directional means that the lower head
must trigger first for the device not to
send an alarm signal.
On = Directional
4
Test Mode
Off = Normal
Enables head LEDs and buzzer for
testing. ( JP4 must be closed for
buzzer to sound)
On = Test Mode
5
Supervision
Off = 90 minutes
This is the interval that the device waits
between supervision signals that are
sent to the X-Series alarm
On = 12 Hours
6
Continuous
detection
Off = Quiet time
Once the device has triggered it will
wait 30 seconds before triggering
again. If during the 30 seconds
movement is seen the 30 seconds is
reset and the countdown starts again
On = Continuous

Other manuals for IDS X64

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDS X64 and is the answer not in the manual?

IDS X64 Specifications

General IconGeneral
Keypads8
Stay/Away ArmingYes
Tamper ProtectionYes
Operating SystemProprietary
Supported ProtocolsContact ID, SIA
Power Supply16.5VAC
Backup Battery12VDC 7Ah
AlertsSMS
RAMUnknown

Related product manuals