Auto Arm and Auto Alarm | IDS X Series Training V2.3
Auto Arm and Auto Alarm
Each partition can be set to automatically arm or alarm with a medical signal if no movement is detected
within a certain time period.
Arm on no Movement
Each partition can be set to automatically arm if no movement is detected within a certain time period.
There are 3 steps that need to be completed:
Location 165: Auto Arm Time Out
Location Type: Extended
There is a sub-location for each of the 8 partitions.
This is the time the panel will wait before beginning to arm, once all movement has stopped.
If movement is detected within this time, the system resets and waits for the movement to stop.
Format: HHMM
Default: 0000
Valid range: 0000 to 2359
Location 166: Auto Arm Start Time
Location Type: Extended
There is a sub-location for each of the 8 partitions.
The time entered here in the 24 hour format (HHMM) is when the system will start to monitor for no
movement.
Format: HHMM
Default: 0000
Valid range: 0000 to 2359
Location 167: No movement auto arm stop time
Location Type: Extended
There is a sub-location for each of the 8 partitions.
If movement has not stopped when this time (HHMM) has been reached the system stops monitoring for
no movement.
Format: HHMM
Default: 0000
Valid range: 0000 to 2359
Medical Alarm on No Movement
Each partition can be set to monitor for no movement and if movement is not detected within a certain
period of time, an alarm can be triggered to alert someone of the situation.
There are 3 steps that need to be completed:
Location 168: No movement Medical Alarm Time Out
Location Type: Extended
There is a sub-location for each of the 8 partitions.
This is the time the panel will wait before triggering the alarm, once all movement has stopped.
If movement is detected within this time, the system resets and waits for all movement to stop again.
Format: HHmm
Default: 0000
Valid range: 0000 to 2359

Other manuals for IDS X64

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDS X64 and is the answer not in the manual?

IDS X64 Specifications

General IconGeneral
Keypads8
Stay/Away ArmingYes
Tamper ProtectionYes
Operating SystemProprietary
Supported ProtocolsContact ID, SIA
Power Supply16.5VAC
Backup Battery12VDC 7Ah
AlertsSMS
RAMUnknown

Related product manuals