Location 304 to 335 Zone Reporting
[INSTALLER CODE] [*] [LOCATION] [*] [SUB LOC] [*] [REPORTING CODE] [*]
When the system is armed, a 24Hr zone or a panic zone is
triggered this code is reported
When the zone restores after being violated this code is sent
If the tamper monitoring option is enabled and a tamper signal
is received this code is sent
Once the tamper condition is corrected a restoral is sent
If a zone is bypassed and the alarm is armed this code is sent
to report which zones are inactive
If the system is programmed to automatically bypass zones that
are violated when arming, this code is sent to alert the
monitoring company of inactive zones
Swinger shutdown
reporting
If swinger shutdown has been enabled and the alarm
automatically shuts down a zone that has violated the swinger
shutdown settings
The system can be set to try and restore a zone that has been
disabled by the swing shutdown option and if it is able to
restore the zone this code is sent
Location 336 to 340 Keypad Reporting
[INSTALLER CODE] [*] [LOCATION] [*] [SUB LOC] [*] [REPORTING CODE] [*]
A user code can be programmed to send a duress signal to
alert the security company of a life threatening situation
causing the user to disarm the alarm with this code
Each keypad has a panic button which when pressed can
send a code alerting the monitoring company of a situation
If a fire is detected and the fire key on the keypad is pressed
this code will be reported
A medical code can be sent alerting the monitoring company
to send an ambulance
If a code is entered incorrectly the keypad can be set to lock
for a period of time and sent this code to alert the monitoring
company
Location 342 to 373 User Reporting
[INSTALLER CODE] [*] [LOCATION] [*] [SUB LOC] [*] [REPORTING CODE] [*]
Every time a user arms the alarm this code is sent
If the user arms in stay mode this code is sent
Every time a user disarms the alarm this code is sent
When a user enters their code to cancel the siren this code is
sent