Troubleshooting
12
p.47
1 Troubleshooting
If the product does not function properly, please see the below for trouble shooting.
Problem Action
When I turn on the product, it
does not recognize the card with
just the 3 LED indicators blinking.
1. Check if the product is installed properly and works
normally.
- In the initial setup of the product or after it is initialized
Set the operation mode and register the Master card and
user cards as usual because the product is in the initial
state.
I. 100RV modes available : Mode Number + ENT
RF Only : 01 + ENT
RF + P/W : 02 + ENT
PIN Only : 03 + ENT
RF or PIN : 05 + ENT
II. Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) +
ENT)
III. Enter the user card or PIN number and provide the
password according to the mode
IV. Master Card (or (PIN): 4 ~ 6 digits (Mode 03 or 05) +
ENT)
For more information about registering the Master
Card and the user card, refer to the initial setup
section in the user manual.
2. If this happens while the product is operating normally
(with the Master Card and user card registered) Product
malfunction
I. Power: OFF ON