EasyManua.ls Logo

IFM Ecomat 300 AC1421 - Page 59

IFM Ecomat 300 AC1421
365 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
59
ifm Device Manual SmartSPS AC14 with EtherNet/IP interface (AC1421, AC1422), Firmware 3.1.2 2015-11-30
Menu AS-i 1 / AS-i 2
>
5.3.2 AS-i 1 / AS-i 2: Diagnosis
9039
The [Diagnosis] menu provides access to the diagnostic data of the selected AS-i network.
>
Display and reset the error counters
9042
To display and reset the AS-i error counters:
1 Select the menu page
► > or >
► Select [Error counters] tab.
2 Display the error counters
> Page shows the following information:
Designation
Meaning
Telegrams
Number of message errors that occurred
Configuration
Number of configuration errors that occurred
Voltage < 22,5V
Number of voltage errors < 22.5 V
Voltage < 19,0V
Number of voltage errors < 19.0 V
Earth fault
Number of detected earth faults
3 Optional: reset the error counters
► Press [Reset] button.
> All error counters are reset to 0.
>
Display the error statistics of the AS-i slaves
9087
To display the error messages of the AS-i slaves on the selected AS-i master:
1 Select the menu page
► > or >
► Select [Errors / slave] tab.
2 Display the error statistics of the AS-i slaves
> Page shows the following information:
Column header
Meaning
Adress
Address of the AS-i slave
S/A
Number of errors of the single or A slave at this address
B
Number of errors of the B slave at this address
► Use [] / [] to scroll through the table.

Table of Contents