ecomatController CR720S/CR721S
22
ifm electronic gmbh ● Friedrichstraße 1 ● 45128 Essen We reserve the right to make technical alterations without prior notice! 22 Nov� 2017CR720S / page 3
CR720S Technical data
Control systems
Operating states of the system
LED SYS0 LED SYS1 System state
Colour Status Colour Status
off off no operating voltage
green 5 Hz off no operating system loaded
red on off hardware error (fatal error+)
red on red on system error (fatal error)
green /
yellow
2 Hz green /
yellow
2 Hz update
Operating states PLC / application
LED Co-
lour
Status Description
SYS0 green on
Standard PLC
no application
2 Hz run
red 10 Hz error application (serious error)
yellow 2 Hz debug run
on debug stop
SYS1 green on
Safe PLC
no application
2 Hz run
red 10 Hz error application (serious error)
yellow 2 Hz debug run
on debug stop
ETH0 green ashing data transmission Ethernet
on Ethernet connection OK, no data transfer
ETH1 green ashing data transmission Ethernet
on Ethernet connection OK, no data transfer
APP0
���
APP3
red on status display of the application, freely program-
mable
green on status display of the application, freely program-
mable
blue on status display of the application, freely program-
mable