4 Installation
4.1 Fastening
Fix the controller to a flat surface using 4 galvanized M6 screws�
Tightening torque: 10
±2
Nm
EPS Source
Product Scale Drawing
Frame Size: 80 mm x 49,5 mm
Original Scale Drawing (MTD)
P_MZ_e100_0093
Scale: 1:2
18
47
68,4
18
47
206
219
250
271
6,4 M12x1
LEDs
1
2
Installation
Total height with the attached
connector
NOTE
To avoid contact corrosion between the mounting screws and the module
housing, do not use any stainless steel screws or nickel-plated screws�
In very corrosive environments such as extremely salty air, we recommend to use
screws with surface finishing on a zinc/nickel basis with thick-film passivation and
sealing� For normal corrosive requirements zinc-plated screws are sufficient�