7.2.2 Test standards and regulations
ifm electronic gmbh ● Friedrichstraße 1 ● 45128 Essen We reserve the right to make technical alterations without prior notice! 22 Nov� 2017CR721S / page 4
CR721S Technical data
Test standards and regulations
CE marking EN 61000-6-2 Electromagnetic compatibility (EMC)
Noise immunity
EN 61000-6-4 Electromagnetic compatibility (EMC)
Radiation of interference
EN 61010 Safety requirements for electrical equipment for
measurement, control and laboratory use
E1 marking UN/ECE-R10 Radiation of interference
Immunity with 100 V/m
Electrical tests ISO 7637-2 Pulse 1, severity level: IV; function state C
Pulse 2a, severity level: IV; function state A
Pulse 2b, severity level: IV; function state C
Pulse 3a, severity level: IV; function state A
Pulse 3b, severity level: IV; function state A
Pulse 4, severity level: IV; function state A
Pulse 5, severity level: III; function state A
(data valid for the 24 V system)
Pulse 4, severity level: III; function state A
(data valid for the 12 V system)
Climatic tests EN 60068-2-30 Damp heat, cyclic
Upper temperature 55°C, number of cycles: 6
EN 60068-2-78 Damp heat, steady state
Test temperature 40°C / 93% RH
Test duration: 21 days
EN 60068-2-52 Salt spray test
Severity level 3 (vehicle)
Mechanical tests ISO 16750-3 Test VII; Vibration, random
Mounting location: vehicle body
EN 60068-2-6 Vibration, sinusoidal
10���500 Hz; 0�72 mm/10 g; 10 cycles/axis
ISO 16750-3 Bump
30 g/6 ms; 24,000 shocks