28
FAULT CAUSE TROUBLESHOOTING
E:32-00 will light up alternately or
indicator for water supply lights up.
The flow rate must be at least 10 l/min when
the water supply is open.
The filters in the water connection
of the supply or AquaStop hose are
blocked.
1. Switch off the appliance.
2. Pull out the mains plug.
3. Turn off the water tap.
4. Unscrew the water connection.
5. Remove the filter from the supply hose
6. Clean the filter.
7. Re-insert the filter in the supply hose.
8. Screw the water connection back on.
9. Check the water connection for leaks.
10. Restore the power supply.
11. Switch the appliance on.
E:34-00 will light up alternately. Water is continuously running into
the appliance.
1. Turn off the water tap.
2. Call Customer Service.
E:61-02 will light up alternately. Wastewater pump is blocked. ● Clean the wastewater pump.
→"Clean wastewater pump", Page35
Cover of the wastewater pump is
loose
● Secure the cover of the "Wastewater pump "
→Page35 so it clicks into position.
E:61-03 will light up alternately. Wa-
ter is not drained.
Wastewater hose is blocked or
kinked.
1. Reposition the wastewater hose without
kinks.
2. Remove residues.
Siphon connection is still sealed. ● Check the connection to the siphon and open
if necessary.
Cover of the wastewater pump is
loose.
● Secure the cover of the "Wastewater pump "
→Page35 so it clicks into position.
E:90-01 will light up alternately. Mains voltage is too low. This is not a fault on the appliance.
1. Contact an electrician.
2. Have the mains voltage and electrical installa-
tion checked by an electrician.
E:92-40 will light up alternately. Filters are soiled or blocked. ● Clean the filters.