S T O R A G E & W I N T E R I Z A T I O N
S T O R A G E & W I N T E R I Z A T I O N
Proper storage and/or winterization preparationsareasimpor-
tantashowadrivetrainismaintainedinuse.Sincespecialpreparationsarenecessary,the
boatownershouldhavetheworkdonebyanILMOR-authorizeddealer.Damagethatoc-
cursfromimproperstorageand/orwinterizationisnotcoveredunderwarrantyandmust
beavoided.
Enginewinterizationrequiresaddingafuelstabilizerandbiocidetothefueltank/sys-
tem,changingtheengineoil/filter,drainingallrawwaterfromthecoolingsystem,and
addingmarine/RVanti-freezetoallrawwaterenginecomponents.
Damage due to improper storage and/or winterization preparations is not cov-
ered under warranty. Owners are encouraged to seek assistance from an authorized
ILMOR dealer to properly prepare the drive train for periods of inactivity exceeding
two (2) weeks.
This preparation needs to be done prior to removing water from the engine, if that will be part of
the process.
Boats that are going to be storedforextended
periods(morethantwo[2]weeks)orwinterizedshouldhaveatten-
tionforthefuelsystem.EvenTOPTIERgasolineswillexperience
someseparationofelementsandsettlingduringtheseperiods.Of
considerableconcernisthatwatercondensationwilloccurwithin
thefuelsystem,andwaterisanenemyofgood-startingandrunning
enginefuelsystems.Therefore,followthisprocedure:
•Thefueltankshouldbeninety-to-ninety-fivepercent(90-95%)
fullofTOPTIERgasoline.Thisallowsforminimalroominwhich
aircanoxygenatethefuelduringdiurnalcycles(dailyperiodsof
expansion/contractionofgasolinevaporsandairasaresultoftem-
peraturechanges).Astemperaturesriseinthetank,thepressure
alsorise, pushingoutgasoline vapor-and-airmixtures.Whenthe
temperaturefalls,pressurelowersandthesystemwillseektodrawfreshairandwatervapor
(dependingonthehumiditylevel)intothetank.Freshairisreplacedwith“lightends,which
arelow-boilingcomponentsthatvaporizeatambienttemperatures.Lightendsarerequired
duringcoldstartstovaporizethefuel.Sincethedailydiurnalcycleseliminatethelightends,
anearlyfulltankhelpstominimizetheairvolumeenteringthesystem.
• AddabiocideadditivesuchasValvetectBioguard
TM
FuelBiocideinthefueltanktolimitmi-
crobialgrowthingasoline.Followthedirectionsprovidedbythestabilizersmanufacturer.
• Addafuelstabilizer,suchasSta-Bil
®
,tothefueltank.Followthedirectionsprovided
bythestabilizer’smanufacturer.
Fuel System
Treatment
2011 ILMOR MV8 Owner’s Manual • Page 37