OPERATING AND PROGRAMMING INSTRUCTIONS
4-3
Indicator for humidity sensor is operating. (Optional)
Indicator when a malfunction occurs.
Show on the working temperature 90 ° C (High Heat).
Show on the working temperature 82 ° C (Medium Heat).
Show on the working temperature 65 ° C (Low Heat).
Show when the program is running without a temperature 0 ° C (No Heat).
1. Energize the electrical circuit to the tumbler at the disconnect switch or the circuit
breaker. The display is show “t002” about 3 second and then show P1 – P10.
2. Press Up and Down button together the display is show ---- and then put the password
(9999)
3. Press the Down button to enter the password for each digit, press the Enter button to
move. When entering the password, press Enter, and then select the desired setting (C1 -
C10) and then press the Enter key again to enter the program. This can be set up as
follows.
3.1 Time Setting
- Setting time for drying. Can be set from 0 – 240 minutes.
- Setting a time for cool down. Can be set from 0 – 240 minutes.
NOTE: During Running the machine on the moniter show A-Z that it means time over 100
minute.