OPERATING AND PROGRAMMING INSTRUCTIONS
4-5
- PaSS: (change the password) can change the password.
- tFtr: (setting Forward / Reveres) can be set at the turn of the basket is a Forward /
Reverse.
- trot: (set the rotation of the basket) can be set from 3 – 90 seconds.
- tstP: (set time to stop rotation of the basket) can be set to stop the rotation of the
basket from 0-60 seconds.
- Anti: (set to anti crease) can be set to anti crease.
- trEF: (the reference temperature) is the temperature. Has the same value as the
program runs.
- buZZ: (warning time) can set the alarm time from 0-99 seconds, but if it is set to 0,
the alarm always.
- AtEd: (the end of operation setting) can be set to working by the end of which the
time or the temperature is set to 0, it will be the end of the working of time. If set to
1 to 99 to the end of the working the temperature.
- dtP1: (the actual temperature at the time) while present temperature setting
- dAEn: Blower auto clean option can setting 0-10 Second.
- UdeN: Setting out put WD relay for use in equipment option (Tilt system/Door lock
system).
- tC: Setting function of the temperature sensor and humidity sensor.
- tC0: Setting function of moisture sensor (Option).
- tC1: Setting function in temperature sensor.
- Unlt: Setting temperature unit (°CEL/°FAH).
- Door is not closed all the way.
- Door switch out of proper adjustment.
- Failed door switch.
- Broken connection / wire in main door circuit.
- Failed 24 VAC transformers.
- Temperature is over than 110 °C
- Temperature is lower than 20 °C
- Drive motor is over current or has failed.
- Blower motor is over current or has failed.
E. MEANING OF THE ALARM MASSAGE