EasyManuals Logo
Home>Immergas>Boiler>HE COMBI INTERNAL

Immergas HE COMBI INTERNAL User Manual

Immergas HE COMBI INTERNAL
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
MAINTE
NA
N
C
E T
E
CHNICIAN
USER
INS
T
ALLER
3.17 COMBUSTION PARAMETERS.
NG (G20)
LPG (G30)
Gas nozzle diameter
1,40
0,85
Supply pressure
kPa
1,0
2,8
Flue
ow
rate at
nominal
heat output
58
60
Flue
ow
rate at min heat output
59
63
CO
2
at Nom Q./Min.
%
7,75 / 3,30 8,90 / 3,75
CO with 0% O
2
at Nom Q /Min.
ppm
55 / 11 78 / 29
NO
X
with 0% O
2
at Nom Q /Min.
170 / 41
240 / 46
Flue temperature at nominal output
°C
67
68
Flue temperature at minimum output
62
61
3.18 TECHNICAL DATA.
Heat input N
G
MJ/h (kW)
124,2 (36,2)
Heat output NG MJ/h (kW) 126 (34,9)
CH
minimum
heat output MJ/h (Kw) 53.9 (14.9)
Burner pressure maximum NG/LPG
kPa
0.70/2.10
Burner pressure minimum NG/LPG
kPa
0.19/0.55
Heat input LPG MJ/h (kW) 124.2 (36.2)
Heat output LPG MJ/h (kW) 130 (34.9)
CH minimum heat input
MJ/h (kW)
45,7 (14,9)
ie
ncy 80/60 Nom./Min.
%
96,5 / 92,9
ie
ncy 50/30 Nom./Min.
%
102,0 / 99,1
Heat loss at casing with burner On/
%
0,50 / 0,59
Heat loss at flue with burner On/O
%
3,00 / 0,01
Central heating circuit max. operating pressure
kPa
300
Central heating circuit max. operating temperature
°C
90
Adjustable central heating temperature
°C
35 -
85
System expansion vessel total volume
l
5,1
Expansion vessel factory-set pressure
bar
1
Pressure relief setting bar (psi) 3 (44)
Expansion vessel capacity
L
10
Water content in generator
l
4,0
Head available with 1000 l/h ow rate
kPa (m H
2
O)
30,2 (3,1)
Internal pump head
(kPa)
Hot water production heat output
MJ/h (kW)
126 (34,9)
Speci c ow rate ( t 25
o
C )
l/min
20
Domestic hot water circuit max. working pressure
kPa
1000
Min. pressure (dynamic) domestic hot water circuit
kPa
30
Minimum D.H.W. ow rate
l/min
1.5
Weight of full boiler
kg
49
Weight of empty boiler
kg
45
Electrical connection
V/Hz
230/50
Power input
A
1
Installed electric power
W
175
Pump consumption
W
95
Fan power consumption
W
65
Equipment electrical system protection
-
IPX5D
NO
X
class
-
3
Weighted NO
X
mg/kWh
110
Weighted CO mg/kWh
81
V 4.7m
H
3.0m
V12.2m
H 7.3m
V 40m*
H 20m*
Type of appliance
C12 /C32 / C42 / C52 / B22 / B32
- Flue temperature values refer to an air inlet
temperature
of 15°C.
approved with the HE 30 COMBI INTERNAL,
components 60/100 and 80/125 mm.
- The max. sound level emitted during boiler
operation is < 55dBA. The sound level value is
referred to semianechoic chamber tests with
boiler operating at max. heat output, with
extension of flue gas exhaust system according
to product standards.
-
25

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Immergas HE COMBI INTERNAL and is the answer not in the manual?

Immergas HE COMBI INTERNAL Specifications

General IconGeneral
BrandImmergas
ModelHE COMBI INTERNAL
CategoryBoiler
LanguageEnglish

Related product manuals