Instructions and recommendations
Installer
User
Maintenance technician
*1.045009ENG*
*1.045009ENG*
IE
MYTHOS HP

Questions and Answers

  • A
    Angela DoughertyAug 13, 2025
    How to address gas smell from Immergas MYTHOS HP Boiler?
    • E
      elizabeth23Aug 13, 2025
      If you smell gas from your Immergas Boiler, it's likely due to a leak in the gas circuit pipelines. You should check the sealing efficiency of the gas intake circuit to resolve this issue.
  • J
    Jonathan NicholsAug 17, 2025
    What to do if Immergas MYTHOS HP Boiler overheating safety device trips frequently?
    • J
      Julian RiveraAug 17, 2025
      If the overheating safety device thermostat function trips frequently on your Immergas Boiler, it could be due to a few reasons: * Lack of water in the boiler. * Poor water circulation in the system. * Blocked circulating pump. Check the system pressure on the pressure gauge to ensure it's within the established limits. Also, make sure the radiator valves are open and that the pump is functioning correctly.
  • G
    Gary LewisAug 21, 2025
    Why does my Immergas Boiler have repeated ignition blocks?
    • X
      xsharpAug 21, 2025
      If your Immergas Boiler experiences repeated ignition blocks, it could be due to: * No gas supply: Check that there is pressure in the network and the gas cock is open. * Clogged condensate drain: Restore the function of the condensate drain, ensuring the condensate hasn't affected combustion components, the fan, or the gas valve. Also, check the function of the condensate sensor.
  • J
    Joseph WilsonAug 25, 2025
    What does a red pump LED on my Immergas MYTHOS HP mean?
    • C
      Caitlin WongAug 26, 2025
      A red pump LED on your Immergas Boiler indicates a problem. This can be caused by: 1. Low power supply voltage: Wait for the voltage to rise. The LED will turn green when the pump restarts. 2. Rotor locked: Carefully act on the screw in the middle of the head to manually release the crankshaft. Circulation should start immediately, and the LED will turn green. 3. Electrical error: Check the pump, its wiring, and electronics for any faults.
  • D
    David SharpAug 28, 2025
    How to troubleshoot irregular combustion or noisiness in Immergas MYTHOS HP Boiler?
    • D
      Dr. Charles RuizAug 28, 2025
      Irregular combustion or noisiness in your Immergas Boiler can be caused by a dirty burner, a clogged primary heat exchanger, incorrect combustion parameters, or an incorrectly installed intake-exhaust terminal. You should check these components.
  • D
    Dennis GonzalesSep 1, 2025
    What causes a clogged condensing heat exchanger in Immergas MYTHOS HP?
    • S
      sarah83Sep 1, 2025
      If the condensing heat exchanger in your Immergas Boiler is clogged, it's likely due to a blockage in the siphon or the duct between the condensing exchanger and the siphon. Check that there are no residues of material blocking the flow of condensate.
  • P
    philipcainSep 5, 2025
    What to do if the siphon is blocked in Immergas Boiler?
    • M
      Mrs. Teresa DurhamSep 5, 2025
      A blocked siphon in your Immergas Boiler is usually caused by dirt or combustion products deposited inside. To resolve this, check that there are no residues of material blocking the flow of condensate.
  • C
    Christian GuerreroSep 9, 2025
    What causes poor D.H.W. production in Immergas Boiler?
    • R
      Robert HowardSep 9, 2025
      Poor production of D.H.W. in your Immergas Boiler is likely due to a clogged DHW heat exchanger. Contact Immergas After-Sales Assistance Service, they have procedures to clean the D.H.W. heat exchanger.

Summary

Boiler Installation Guide

Installation Warnings and Safety

Essential safety and installation warnings for qualified personnel.

Gas and Hydraulic Connections

Procedures for connecting gas and hydraulic systems to the boiler.

Electrical Connection and Safety

Guidelines for safe electrical connections and earthing requirements.

Flue System Installation

Instructions for installing Immergas flue systems for safe exhaust.

Boiler Operation and Maintenance

General Recommendations for Safe Use

Essential guidelines for safe operation and maintenance of the boiler.

Control Panel and Operating Modes

Understanding the control panel and operating the boiler in various modes.

Troubleshooting Faults and Anomalies

Identifying and resolving boiler faults and anomaly signals using error codes.

Information Menu and System Checks

Accessing system information and performing diagnostic checks.

Maintenance and Initial Checks

General Recommendations and Initial Checks

General safety recommendations and steps for the initial boiler check.

Yearly Maintenance and Diagrams

Annual maintenance tasks, hydraulic, and wiring diagrams for system understanding.

Troubleshooting and Gas Valve Calibration

Common issues, troubleshooting steps, and gas valve calibration procedures.

P.C.B. Programming and Component Access

Boiler programming options, casing removal, and specific function details.

Technical Specifications and Data

Heat Output and Combustion Parameters

Boiler heat output and combustion parameters for various operating conditions.

Comprehensive Technical Data Table

Detailed technical specifications, performance data, and safety features of the boiler.

Regulatory Compliance and Product Fiche

Technical parameters and product fiche information compliant with regulations.

Immergas MYTHOS HP Specifications

General IconGeneral
BrandImmergas
ModelMYTHOS HP
CategoryBoiler
LanguageEnglish