Why does my Immergas HE COMBI INTERNAL smell like gas?
T
Troy ClarkAug 7, 2025
A gas smell from your Immergas Boiler could stem from several causes. It may indicate a leakage from the gas circuit, which requires checking the L and N polarity. Another reason may be the absence of gas, so it is recommended to check the presence of pressure in the network and ensure that the gas intake pipe is open. An incorrectly adjusted gas valve can also lead to this issue, necessitating a check of the gas valve's calibration. Additionally, ensure that the heat exchanger or trap are not clogged.
J
Jeffrey HallAug 16, 2025
What to do if my Immergas Boiler frequently activates the temperature overload thermostat?
J
Judy VaughanAug 17, 2025
Frequent activation of the temperature overload thermostat in your Immergas Boiler can be due to a lack of water, poor water circulation, or a blocked pump. Ensure the system pressure is within established limits by checking the manometer. Also, verify that the radiator valves are open and that the pump is functioning correctly. Adjust the boiler's minimum heat power and the heating power as well.
J
James GonzalezAug 26, 2025
How to fix noise due to air in the Immergas Boiler system?
H
Heather JonesAug 26, 2025
If you're experiencing noise due to air in your Immergas Boiler system, verify the hood of the special air vent valve is open. Also, make sure that the system pressure and expansion vessel pre-charge values are correct; the expansion vessel pre-charge value should be 1.0 bar.