Page #41 background image
41
Console Panel Functions
10.6 Emergency stop message: ER07
10.6.1 Reset SAFETY switch then press STOP button.
10.6.2 check the mechanical structure.
10.6.3 connection check.
10.6.4 safety key check or replace.
10.6.5 console PCB check or replace.
10.7 The console no power
10.7.1 Check the power voltage by using voltage-meter to see if it is within 220-240V.
10.7.2 The switch is turned to the "ON" position, If the switch light isn't lit, replace
the switch.
10.7.3 Inspect the circuit breaker to see if it has tripped off. If it is tripped off, reset
the breaker. And check which part is short-circuited. Then replace the short-
circuited part.
10.7.4 Check the communication cable and console connection.
10.7.5 Check the communication cable and inverter connection.
10.7.6 Replace the communication cable.
10.7.7 Replace the power cable.