Specications 16 Crane Reference
4004i - Manual # 99904386
7. Use approximately 4’ (1.2 m) of the cable (item #13) to ground both the vehicle battery and auxiliary battery.
Connect one end of the ground cable to the negative terminal on the vehicle battery, and the other end to
bare metal on the truck body. Use a 5/16” (0.79 cm) ring terminal (item #10 - 77040529) to connect to the
truck body.
A
13
7
14
9
POWER
CABLE
BRACKET
GROUND CABLE (GROUND
TO BARE METAL INSIDE
CRANE BOX)
MALE POWER
CABLE CONNECTOR
89044276 (#13)
ON-OFF SWITCH TO FUSE
(CUT TO LENGTH)
WARNING
Install the ground cable to the negative
terminal of the batteries! The crane electrical
ground completes the electrical circuit
through the structure of the crane to the
vehicle frame. The vehicle factory ground is
NOT sufficient to carry the current required by
the crane. Without this extra ground cable,
your crane may not operate at rated capacity,
and motor, contactor, or electrical damage
may occur.