2. Check supply and fluid lines (damage and leakage). Supply and fluid lines must
be checked for damage. Pre-damage such as kinks or abrasions should be
logged and replacement should be initiated.
3.
Example: Various silencer versions from FESTO
Check silencer, replace if necessary
4. Drain condensate (not applicable to auto-drain).
5.
Replace activated carbon filter (by FESTO)
X
Filter base housing
Y Filter bowl
1 Sealing ring
2 Activated carbon filter cartridge
3 O-ring
Check activated carbon filter, replace if necessary. When disassembling the
filter bowl, make sure that sealing rings and O-rings (1 + 3) are also
installed. Unscrew filter bowl (Y) from filter base (X) and remove activated
carbon filter cartridge (2). Check sealing rings and O-rings (1 + 3) , replace if
necessary. Reinstall all parts in reverse order.
Maintenance Summary - Care activities
16
Maintenance Instructions
G200.3 G220.3
DIE248EN - 15.08.2022