6.
Example: Exploded view of fine filter replacement (by FESTO)
1
Filter bowl
2 Separating disk
3 Filter cartridge (check filter fineness)
4 Filter receptacle
5 O-ring
Check fine filter or microfilter, replace if necessary. When removing the filter
bowl, be sure to include the O-ring (5), separating disk (2), and filter
receptacle (4). Unscrew filter bowl (1) from filter base body and remove filter
cartridge (3) , check, and replace if necessary. Check O-ring (5) , replace if
necessary. Reinstall all parts in reverse order.