Application Note 11 of 31 Rev. 1.30
2022-03-01
Current Sensor TLI4971
Programming Guide and User Manual
3.3 Interface Commands
Table 5 Available Commands
Command name
address
hex
command
hex
description
Enter Interface command
---
ABCD
hex
Activate communication as described in
chapter Entering Communication Mode
Power down ISM
25
hex
8000
hex
reserve if-access to the EEPROM data bus to
avoid that ISM is blocking the data bus
Disable failure indication
01
hex
0000
hex
Prevent unintended activation of the OCD2
output
Write command
40
hex
to 42
hex
8400
hex
Initialize Write command to address 40
hex
Send values
XYXY
send data XYXY to previous addressed line
where XYXY stand for 16bit data
placeholder
Read command
40
hex
to 51
hex
0400
hex
Initialize read command at address 40
hex
Read command
41
hex
0410
hex
Initialize read command at address 41
hex
read data from previous address 40
hex
Read command
51
hex
0510
hex
Initialize read command at address 51
hex
read data from previous address
NOP
FFFF
hex
No operation command, to read former
addressed values.
EEPROM margin test ones
3E
hex
0044
hex
Compare cell voltages of programmed ones
EEPROM margin test zeros
3E
hex
0045
hex
Compare cell voltages of programmed
zeros
EEPROM set zeros
3E
hex
0248
hex
Set EEPROM bits to zero
EEPROM set ones
3E
hex
024B
hex
Set EEPROM bits to one
EEPROM refresh
3E
hex
024C
hex
Refresh the all EEPROM lines
EEPROM program zeros
3E
hex
024E
hex
Program all set zeros into EEPROM
EEPROM program ones
3E
hex
024F
hex
Program all set ones into EEPROM