Application Note 9 of 31 Rev. 1.30
2022-03-01
Current Sensor TLI4971
Programming Guide and User Manual
2.4 Interface Timing Definition
Table 1 Interface timing
One communication frame consist of
16 x 2 bits (16bits write / 16bits read)
The device drives A
OUT
to V
DD
by
default.
The device drives A
OUT
to V
DD
by
default.
Drive A
OUT
to GND
t
4
= 2 * ABS(t
1_x
- t
2_x
)
t
3
can be set as applicable. Increase of
t
3
will reduce sensor response time t
4
.
Therefore t
r
has to be set accordingly
The device drives A
OUT
to V
DD
by
default. Set the external controller in
tri state.
t
3
can be set as applicable. Increase
of t
3
will reduce the response time t
4
.
Only valid for a single bit high time.
There is no restriction in timing
between two commands
There is no timing restriction between two commands as long as the A
OUT
pin is not driven to GND.
The typical threshold level to detect a logic “0” during a high to low transition is 1.3V.
The typical threshold level to detect a logic “1” during a low to high transition is 1.6V.
2.5 Definition of Voltage Levels
Table 2 SICI High and low level definition
Voltage level for SICI – High