6.2. Dip Switches
There are four DIP switches located on the top panel of the InSwitch. Each DIP switch has either
an ON or OFF state, controlling one of the switches functions. In the following diagram, all of the
switches are in the ON state.
Connection disruption alarm for optical port one
OFF = Disabled
ON = Enabled
Connection interruption alarm for optical port two
OFF = Disabled
ON = Enabled
Broadcast storm control function
OFF = Broadcast storm control disabled
ON = Broadcast storm control enabled
Flow control
OFF = Flow control disabled
ON = Flow control enabled
Note:
For type ISE2XXX products, switches one and two corresponds to
alarms for disrupted connections on FX1 and FX2 respectively. If the
FX2 port is not included on your model number, then dip-switch 2 is not
used.
For type ISE3XXX products, position 1 and 2 corresponds to alarm
for disrupted connections on GX1 and GX2 respectively. If the GX2
portis not included on your model number, then dip-switch 2 is not used.
If an optical port is not included on your specific model, then both
switches one and two are not used.