EasyManua.ls Logo

INIM Electronics Prime Series

INIM Electronics Prime Series
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 The control panel and peripherals
Anti-intrusion control panels
The following table shows the maximum number of devices supported by the various control
panel models.
Table 2-2: Type SD and distribution of the currents
Prime control panel models Prime060S Prime060L Prime120L Prime240L
SD type
(backup battery)
rated voltage 12V
maximum capacity 7Ah 9Ah 7Ah 9Ah 7Ah 9Ah 17Ah 18Ah
maximum recharge time 24h (80% charged)
maximum internal resistance (R
i max
)
1.50Ohm 0.50Ohm
Maximum deliv-
erable current @
12V
total 3.7A 6.2A
for external loads
autonomy 30h
(
a
)
50mA 120mA 50mA 120mA 50mA 120mA 380mA 420mA
autonomy 12h
(
b
)
400mA 570mA 400mA 570mA 400mA 570mA 1230mA 1320mA
autonomy 4h (
c
)
1570mA 2070mA 1570mA 2070mA 1570mA 2070mA 4070mA 4320mA
Max. current available on each +AUX terminal 1500mA
Maximum deliverable current to open-
collector outputs
T1, .., T10 250mA
OC1, OC2 500mA
a. The system autonomy in absence of the primary power source can be limited to 30h for systems with security grade 3 or 4, that is,
as long as the primary power source failure is notified to an alarm receiving centre or to another remote control panel.
b. If the system is declassified to grade 2, autonomy can be limited to 12h.
c. For type A or B power supplies, if the system includes an ancillary power supply that switches automatically between the primary
power source and the ancillary power-supply, the autonomy can be limited to 4h regardless of the system security grade.
Table 2-3: Control panel - main features
Prime control panel models Prime060S Prime060L Prime120L Prime240L
Partitions 10 20 30
Total zones 120 240 480
Keypads 10 15
Voice memo slots 10
Expansions 40
Readers 20 30
Sounder/flashers 10
Air2-BS200 Transceivers 20 30
Digital keys and wireless command devices 150
Possible key combinations 4294967296
IB200 isolators 16
GSM/GPRS/2G/3G Communicators 1
Codes 50 100
Scenarios 30 50
Timers 20 40
Recordable Events 4000
Programmable events 30 50 60
Table 2-4: Number of terminals
Prime control panel models Prime060S Prime060L Prime120L Prime240L
Termina l s on pan e l
total 10
configurable as inputs 10
configurable as rollerblind/shock 10
configurable as outputs 10
terminals on keypads 30
terminals on expan-
sion boards
total 200
available 60 120 200
Total terminals 60 120 240

Other manuals for INIM Electronics Prime Series