Installation manual
The control panel and peripherals 27
2-4
SmartLogos30M voice board
The SmartLogos30M voice board is an optional board that is necessary if voice functions are to
be provided by the system:
Voice mailbox, to record, play and delete voice messages.
Voice dialler, to send voice calls to programmed contact numbers.
Answerphone, to answer incoming calls.
After a pre-set number of rings, the control panel will pick-up and play the recorded
answer message. During the call, the recipient can type-in a valid PIN (enabled for over-
the-phone control) and access the authorized functions.
The SmartLogos30M voice board provides 500 voice message slots, 310 of which are pre-
recorded at factory. The messages are arranged in such way as to produce event-related voice
calls which clearly describe the related event.
2-5
PrimeLAN ethernet interface
Prime control panels have the ability to connect directly to LANs and to the Internet.
Network connectivity allows the installer to remotely program and supervise the system via
LAN using Prime/STUDIO software, a web-browser, the AlienMobile application or Cloud
connection.
Using the optional PrimeLAN network board provides the user with additional features, such
as:
sending e-mails with attachments in relation to the control panel events
interaction with the control panel via any browser thanks to an integrated web server. The
web interface, after user authorization, allows you to:
•• view the status of zones
•• view status of outputs
•• view status of partitions
•• view the status of timers
•• view status of the Nexus
•• view contents of the events log
•• faults
•• view virtual keypads
•• view graphic maps
•• view system voltage
•• manage Onvif cameras (real time and video events)
interface with KNX protocol systems
interface with Modbus protocol systems
Thus the user will be able to arm/disarm partitions, bypass/unbypass zones, activate/
deactivate the alarm and tamper memories.
For a more detailed explanation of how to use the Web interface, refer to the User Manual of
the control panel in use.
Table 2-32: PrimeLAN - electrical and mechanical features
Supply voltage
12V
Maximum current draw
30mA
Operating temperature
from -5 to +40 °C
Dimensions
50 x 73 x 19 mm
Maximum capacity of the μSD-card
32Gbyte
Security protocol
128-bit AES