48 First power up
Anti-intrusion control panels
Chapter
4
First power up
On first power up, the control panel initializes the parameters at default (factory settings).
In addition, the control panel automatically enrolls all the peripherals it “sees” on the I-BUS
(automatic addressing phase).
The default address of all expansions, keypads and readers is address 1, therefore, if the
system is equipped with more than one of each type of device, the automatic enrolling
operation will be erroneous.
In order to allow the system to perform an accurate auto-enrolling operation on "First power-
up", work carefully through the following steps.
ATTENTION!
When wiring the system, ensure that no power from the mains (230V
~
) or backup battery
reaches the control panel or any of its peripherals.
1. Attach the control panel to the wall.
2. Complete the wiring of the peripherals to the BUS.
3. Connect the BUS wires to the control panel.
4. Complete the wiring and balancing of the system detectors.
5. Connect the detectors to the terminals.
6. Connect the outputs to the control panel and peripheral terminals.
7. Connect the control panel to the telephone line.
8. Connect the SmartLogos30M board to the appropriate connector on the control panel
motherboard.
9. Insert the maintenance jumper in the “SERV” position.
10. Connect the primary power source (230V
~).
11. Connect the buffer battery and the thermal probe.
The first line of the display of each keypad in the system will show the 'Maintenance'
message and the keypad address at default. On first power up (first startup), all the
keypads will show "K01" (refer to paragraph 3-1-9 Maintenance status).
Note
If several keypads are connected to the I-BUS, their displays may be blank. If this occurs, disregard this
aspect and go directly to the next step.
12. Address the peripherals (refer to paragraph 3-3 Addressing the peripherals). At least
one keypad must be assigned to address 1. Using keypad 1, initialize the addressing
phase for nBy/S and nBy/X readers (refer to paragraph 3-3-5 Addressing nBy readers).
13. From the installer menu, start the self-enrolling process of zone balancing (refer to the
Programming manual, Chapter 17, Parámetros de fábrica, Learn zone bal.).
ATTENTION!
During this phase it is essential that all partitions are at in stand-by status.
14. If present, specify the expansion terminals simulated by the Air2-BS200 transceiver as
“Wireless” terminals (refer to the Programming manual, Chapter 6, Programación de
los terminales)
15. If the installation requires the use of a telephone communicator, program the telephone
numbers for the voice and digital dialer (refer to the Programming manual, Chapter 11,
Programación del teléfono).
16. Remove the maintenance jumper from the “SERV” position and place it in the “RUN”
position.