42 Installation
Anti-intrusion control panels
3-3-5
Addressing nBy readers
To assign addresses to the system readers (with the exception of the built-in readers of
keypads), follow the instructions described in paragraph 3-3-5 Addressing nBy readers or
work carefully through the following steps:
1. Put the control panel in “Maintenance” mode (paragraph 3-1-9 Maintenance status).
2. Start the “Address Programming” phase using the software or from a keypad:
Via software
Click on the Proximity readers button in the menu on the left, then access the Proximity
reader address configuration option in the “Programming - Parameters” section on the
right.
Via keypad
Type-in Code
(Installer)
, PROGRAMMING Readers , Prog. Address
3. Each reader indicates its own address on its LEDs (refer to the Table in paragraph 3-3
Addressing the peripherals).
4. Hold a valid key in the vicinity of the reader. The reader will run through a series of
available reader-addresses (an address every 2 seconds). Remove the key when the
LEDs indicate the desired address.
5. The reader will hold the addressing phase for a further 10 seconds, in order to allow you
to change the address if necessary.
6. The reader will assign the selected address when the 10 second period expires.
7. If you wish to assign an address to another reader, hold a valid key in the vicinity of the
reader and work through points 4 to 6.
8. End the reader-address programming phase initialized at point 2 by exiting the “Prog.
Address” menu via keypad or, if you are using the Prime/STUDIO software, by clicking
on End Proximity reader address configuration.
Note
This procedure does not apply to readers that are built into the keypads.
3-4
Auto-enrolling peripherals
The peripherals connected to the BUS are enrolled automatically in the following situations:
on first startup (refer to Chapter 4, First power up)
in “Maintenance” mode (refer to paragraph 3-1-9 Maintenance status)
from the installer menu (refer to the Programming manual, Chapter 17, Parámetros de
fábrica):
Type in Code
(Installer)
, PROGRAMMING Factory settings , Auto enroll periph.
3-5
Wiring and balancing alarm
detectors
The wiring and respective balancing method depend on the type of detector you are installing,
and the level of protection you wish to achieve. The detectors can be powered through:
terminals [+AUX/12V] and [-/GND] on the control panel
terminals [+AUX/12V] and [-/GND] on FLEX5 expansions
terminal [+/12V] and terminals [-/GND] on keypads
from any 12V ancillary source on condition that its GND reference is in common with that
of the control panel.
The resistors used for balancing are:
•• 3K9Ohm 1/4W
•• 6K8Ohm 1/4W
The following Table indicates the protection level of each detector type and the balancing
options provided by the control panel:
Orange
Red
White
Gold
Red
Grey
Blue
Gold
3K9 Ohm
1/4W
6K8 Ohm
1/4W
Table 3-6: Protection level
BALANCING N.O. N.C. Single Double Double zone
Double zone
with EOL
PIR or Dual technology
very low low medium high medium high
Magnetic contact
very low low medium / medium high