Installation manual
Installation 41
3-3-1
Fast addressing of keypads and readers
If, within 4 seconds of inserting the maintenance jumper (Table 2-6: Mother board -
description of parts, J) the open-tamper microswitch is pressed on the control panel frontplate
(Table 2-6: Mother board - description of parts, B), the Prime system will activate the function
for the fast addressing of keypads and readers.
All the keypads and readers connected to the I-BUS will be placed in address programming
status and assigned their addresses in sequential order.
At the point, you (the installer) can either change or confirm the assigned addresses.
3-3-2
Addressing the keypads
To assign addresses to keypads, follow the procedure described in paragraph 3-3-1 Fast
addressing of keypads and readers or work through the following steps:
1. Put the control panel in “Maintenance” mode by inserting the respective jumper (Table
2-6: Mother board - description of parts, J).
2. Using the keypad you want to address, press and release keys and simulta-
neously; set the desired address then press OK.
3. If the keypad has a built-in reader, enable or disable the reader by pressing key or
.
4. If the keypad is enabled, set the address and press OK.
5. Enable or disable the anti-dislodgement tamper switch by pressing key or .
6. Enable or disable the anti-opening tamper switch by pressing key or .
Note
For security reasons, if the address is not assigned within 30 minutes of accessing “Maintenance” mode
(SERV jumper inserted), the keypad will exit the programming phase automatically.
3-3-3
Addressing the Alien keypad
Work carefully through the following steps.
1. Put the control panel in “Maintenance” mode (paragraph 3-1-9 Maintenance status).
2. From the Alien keypad, access the “Settings” section by pressing the “Settings” button
and then access the “Alien” section. This section provides a list of the keypad parameters.
3. Set the parameters:
• PROXY ADDRESS - Alien keypad address
• PROXY ADDRESS - built-in reader address
• ALIEN TAMPER - keypad tamper enablement
4. This parameter can be changed by means of keys + and -.
5. Tap SAVE to set the addresses and exit.
3-3-4
Addressing FLEX5 expansion boards
Using a small screwdriver or similar tool, set the expansion board address on the 8-segment
DIP-Switch strip (Table 2-28: Flex5 - description of parts, C). Each segment can be set at “1”
(On) or “0” (Off).
The figure shows some examples.
The address of the Flex5/DAC board is assigned through its programming menu (refer to the
attached manual).
keypad address
_1
Min. 01
Max. 30
Expansion n. 1
Expansion n.29
Expansion n.40
Position 1
Position 2