Installation manual
First operational test 49
Chapter
5
First operational test
A procedure is provided for an operational test on the Prime system after installation. The test
consists in the violation of a "Delayed" type zone.
This procedure must be carried out only after the complete installation of the Prime control
panel and of all the components that make up the entire installation. To do this it is advisable
to follow the instructions provided in Chapter 4, First power up.
1. Make sure all partitions are in stand-by status.
This status is signalled on the blue LED on the keypad or the blue icon on the Alien key-
pad when the latter is ON solid.
2. Enter the control panel programming phase and program the partition you intend to
violate.
Via software
To program the zone to be tested, click-on the Terminals button. The “Programming” section
on the right will show an illustration of all the terminals on the entire system.
By double clicking on the terminal concerned you will enter the terminal programming phase.
Set “Delayed” as the “Type”.
Via keypad
Type in Code
(Installer)
, PROGRAMMING Terminals,
select the terminal concerned
or
Type-in Code
(Installer)
, PROGRAMMING Zones,
select the zone associated with the terminal concerned
Once the section has been accessed, set the “Type” as “Delayed”.
3. Set up the telephone dialer to provide voice signalling of violation.
Via software
To program voice signalling via the telephone dialer, click-on the Telephone button. The
“Programming” section on the right will show a list of all the available telephone numbers.
By selecting the telephone number “1” from the list, it is possible to modify the parameters. In
this case it is necessary to enter the number to call and set the “Type” as “Voice”.
Via keypad
Type in Code
(Installer)
, PROGRAMMING Telephone, Number selected,"NUMERO 001".
Once in this section it is necessary to enter the number to call and set the “Type” as “Voice”.
4. Exit the programming phase and carry out an Away Arming operation.
If the default programming has not been changed, it can be carried out as follows:
Via keypad
Activate the “Arm/Disarm” shortcut (shortcut no. 1) associated with the button shown
on the display.
Via Alien
Press the Scenarios button. This section provides a list of the scenarios which can be
activated by means of the ACTIVATE button.
5. Wait until the “Exit Time” expires (30 seconds by default).
The keypads will emit a series of pulses (3 pulses + 5-second pause, 4 short pulses +
5-second pause during the last 20 seconds of the exit time).
6. Violate the programmed zone.
TEST ENTRY TIME
7. Being a “Delayed” type zone, the “Entry Time” will begin (30 seconds by default).
The keypads will emit a series of pulses (8 pulses + 5 second pause).
TEST ALARM
SIGNALLING
8. If the arming scenario is still active when the entry time expires, alarm signalling will
trigger:
The visual and audible alarm signals will activate
The red LED on the keypad or the red icon on the Alien interface will blink rapidly
Terminal xyz