EasyManua.ls Logo

Inovance IMC30-6G Series - Description and Wiring of PWM Output Interface

Inovance IMC30-6G Series
37 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 16 -
3 Hardware Connection
It is recommended to place the di󶍽erential-to-single-ended
module close to the 24 V single-ended triggering device to
make the advantages of the di󶍽erential signal in long-distance
transmission and strong anti-interference.
3.2 Description and Wiring of PWM Output Interface
PWM/AD
5
4
3
2
1
9
8
7
6
Table 3-2  De󶍾nition of PWM output interface
Pin Signal Description
Electrical
Speci󶍾cations
1 PWM_0+
PWM di󶍽erential output channel 1, twisted pair
for this di󶍽erential signal
RS422
di󶍽erential
output
6 PWM_0-
2 PWM_1+
PWM di󶍽erential output channel 1, twisted pair
for this di󶍽erential signal
7 PWM_1-
3 DGND Digital ground/Di󶍽erential reference ground
8 DGND Reference digital ground of di󶍽erential signal
4 Reserved Reserved -
9 Reserved Reserved -
5 Reserved Reserved -