- 30 -
3 Hardware Connection
◆
To ensure normal operation of the mechanical limit (LMT) and
home (HOME), use external power supply, and connect EX_24V to
24 VDC power and EX_0V to 0 V.
◆
Note that the mechanical limit (LMT) and home (HOME) are single
polarity input, which is dierent from the general input.
3.8 Description and Wiring of Power Interface
Table 3-8 Denition of power interface
Pin Signal Description
1 24V 24 VDC power input
2 0V 24 VDC ground
3 PE Housing ground