- 81 -
Function
code
Name LED display Setup range
Minimu
m unit
Factory
default
value
Modific-
ation
descrip-t
ion
F8-23
Running time to
action selection
Running time to
action selection
0: Continue running
1: Stop
1 0
Group F9 Fault and Protection
F9-00
Motor overload
protection
selection
Overload
protection
selection
0: Inenabled
1: Enabled
1 1
F9-01
Motor overload
protection gain
Overload
protection
coefficient
0.2010.00 0.01 1.00
F9-02
Motor overload
pre-warning
coefficient
Overload
pre-warning
coefficient
50%100% 1% 80%
F9-03
Stall gain over
voltage
Stall gain over
voltage
0(No stall over
voltage)
1 0
F9-04
Stall protection
voltage over
voltage
Stall point over
voltage
120%150% 1% 130%
F9-05
Stall gain over
curren
Stall gain over
curren
0100 1 20
F9-06
Stall protection
current over
current
Stall point over
current
100%200% 1% 150%
F9-07
Transient stop/
non-stop function
Transient stop/
non-stop function
0: Inenabled
1: Enabled
1 0
F9-08
Transient stop/
non-stop
frequency falling
rate
Transient stop/
non-stop
frequency falling
rate
0.00Hz/s ~
maximum
frequency/s
0.01Hz/s
10.00Hz/
s
F9-09
Fault auto reset
times
Fault auto reset
times
03 1 0