3 Operating Panel (Keypad & Display)
- 16 -
Parameter Unit Indicator
Indicator appearance Meaning
RPM
%
A VHz
Hz for frequency
RPM
%
A VHz
A for current
RPM
%
A VHz
V for voltage
RPM
%
A VHz
Rpm for motor speed
RPM
%
A VHz
Percentage
Keys on Operation Panel
Key Key name Function
PRG
Programming Enter or exit level i menu�
Return to the previous menu�
ENTER
Conrm Enter each level of menu interface�
Conrm displayed parameter setting.
Increment When navigating a menu, it moves the selection up through the screens available�
When editing a parameter value, it increases the displayed value�
When the servo drive is in run mode, it increases the speed�
Decrement When navigating a menu, it moves the selection down through the screens available�
When editing a parameter value, it decreases the displayed value�
When the servo drive is in running mode, it decreases the speed�
Shift Select the displayed parameter in the stop or running status�
Select the digit to be modied when modifying a parameter value
RUN
Run Start the servo drive when using the operating panel control mode�
It is inactive when using the terminal or communication control mode�
STOP
RES
Stop/reset Stop the servo drive when the drive is in the running status�
Perform a reset operation when the drive is in the fault status� Note: the functions of this
key can be restricted by using function F7-02�
MF
.K
Multifunction Perform a function switchover as dened by the setting of F7-01, for
Example to quickly switch command source or direction�
QUICK
Menu mode selection Press it to switch over between menu modes as dened by the setting of FP-03.