EasyManua.ls Logo

Inovance IS580T080 - 5.3 Monitoring Parameter List

Inovance IS580T080
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Parameter Table
- 40 -
5�3 Monitoring Parameter List
Para� No� Para� Name Setting range Unit
Group U0: Drive Status Monitoring
U0-00 Running frequency -650�00 to 650�00 0�01 Hz
U0-01 Frequency reference -650�00 to 650�00 0�01 Hz
U0-02 DC bus voltage 0�0 to 1000�0 V 0�1 V
U0-03 Output voltage 0 V to F02�03 1 V
U0-04 Output current 0�1 to 6553�5 A 0�1 A
U0-05 Output power 0�4 to 1000�0 kW 0�1 kW
U0-06 Output torque 0% to 200% 0�1
U0-07 Basic DI/DO status - -
U0-08 Extended DI/DO status - -
U0-09 AI1 voltage(after correction) -10�00 to 10�000 V 0�001 V
U0-10 AI2 voltage(after correction) -10�00 to 10�000 V 0�001 V
U0-11 AI3 voltage(after correction) -10�00 to 10�000 V 0�001 V
U0-12 Resolver mechanical angle 1 to 4096 1
U0-13 Reserved - -
U0-14 Motor speed -9999 to 32767 rpm 1
U0-15 to U0-18 Reserved - -
U0-19 Speed reference -9999 to 32767 rpm 1rmp
U0-20 Frequency feedback of motor (q15 format) 0 to 65535 1
U0-21 to U0-24 Reserved - -
U0-25 Overload value in total 0 to 36000 1�0
U0-28 Current upon overcurrent fault 0�01 to 655�35 A 0�01 A
U0-29 Overcurrent fault type 1: hardware
2: rmware
1
U0-30 AI1 voltage(before correction) -10�000 to 10�000 V 0�001 V
U0-31 AI2 voltage(before correction) -10�000 to 10�000 V 0�001 V
U0-32 AI3 voltage(before correction) -10�000 to 10�000 V 0�001 V
U0-33 Reserved - -
U0-34 AO1 voltage 0�000 to 10�000 V 0�001 V
U0-35 AO2 voltage 0�000 to 10�000 V 0�001 V
U0-36 Motor e-angle 0�0° to 359�9° 0�1°
U0-37 Pressure command 0�0 kg/cm
2
to A3-02 0�1 kg/cm
2
U0-38 Pressure feedback 0�0 kg/cm
2
to A3-02 0�1kg/cm
2
U0-39 Speed command -9999 to 30000 rpm 1 rmp
U0-40 Speed feedback -9999 to 30000 rpm 1 rmp
U0-41 Motor speed feedback 0 to 65535 1
U0-42 Resolver interference status 0 to 65535 1
U0-43 Reserved - -
U0-44 Reserved - -
U0-45 Motor KTY temperature -40�0°C to 200�0 °C -
U0-46 Received can frames 0 to 65535 1
U0-47 Faulty frames of can sending 0 to 65535 1
U0-48 Faulty frames of can receiving 0 to 65535 1

Table of Contents

Related product manuals