5 Parameter Table
- 30 -
Para� No� Para� Name Setting Range Unit Default Property
F3-23 Voltage limit selection 0 to 1 1 1
F3-24 Frequency gain for voltage limit 0 to 100 1 30
F3-25 Voltage gain for voltage limit 0 to 100 1 30
F3-26 Frequency rise threshold during
voltage limit
0 to 50 1 5
F3-27 Slip compensation time constant 0�1 to 10�0 0�1 0�5
F3-28 Auto frequency boost enable 0 to 1 1 0
F3-29 Minimum torque current 10 to 100 1 50
F3-30 Maximum torque current 10 to 100 1 20
F3-31 Auto frequency boost kp 0 to 100 1 50
F3-32 Auto frequency boost kp 0 to 100 1 50
F3-33 Online torque compensation gain 80 to 150 1 100
Group F4: Input Terminals
F4-00 DI1 function selection 0: no function
1: Forward run (FWD) (oil pump enable)
2: Reverse run (REV)
3: 3 wire control
4: jog forward
5: jog reverse
6 to 7: reserved
8: coast to stop
9: fault reset
10: reserved
11: external fault(normally open)
12 to 17: reserved
18 frequency source switch
19 to 32: reserved
33: external fault(normally closed)
34 to 38: reserved
39: switch from frequency source x to preset
frequency
40: switch from frequency source y to preset
frequency
41 to 47: reserved
48: PID selection 1
49: PID selection 2
50: can communication enable
51: slave pump enable
52: switch from pressure mode to speed mode
(torque upper limit = AI1/max� voltage x A3-30)
53: slave pump address selection 1
54: slave pump address selection 2
55: switch from injection to pressure holding
56: error reset(except overcurrent) 57: switch
from pressure mode to speed mode (torque
upper limit = F2-10)
1 1
F4-01 DI2 function selection 1 48
F4-02 DI3 function selection 1 53
F4-03 DI4 function selection 1 9
F4-04 DI5 function selection 1 50
F4-05 Reserved 1 0
F4-06 Reserved 1 0
F4-07 Reserved 1 0
F4-15 DI lter time 1 to 10 1 4
F4-18 AI1 min� Input -11�00 to 11�00 V 0�01 V 0�02 V
F4-19 AI1 min� Input frequency -100�0% to 100�0% 0�1% 0�0%
F4-20 AI1 max� Input -11�00 to 11�00 V 0�01 V 10�00 V
F4-21 AI1 max� Input frequency -100�0% to 100�0% 0�1% 100�0%
F4-22 AI1 lter time 0�000s to 10�000s 0�001s 0�01s