5 Parameter Table
- 35 -
Para� No� Para� Name Setting Range Unit Default Property
F9-35 The subtype of the second last fault - - - ●
F9-39 Frequency upon the third last fault - - - ●
F9-40 Current upon the third last fault - - - ●
F9-41 Bus voltage upon the third last fault - - - ●
F9-42 DI status upon the third last fault - - - ●
F9-43 DO status upon the third last fault - - - ●
F9-44 The subtype of the third last fault - - - ●
F9-48 KTY temperature reached 0 to 300�0 0�1 0
☆
F9-58 KTY temperature -40�0 to 300�0 0�1 - ●
F9-59 KTY overheat fault threshold -40�0 to 300�0 0�1 130�0
☆
Group FA: Business Countdown Function
FA-00 Password of rst countdown setting 0 to 65535 1 0
☆
FA-01 First countdown 0 to 65535 h 1 h 0
☆
FA-02 Password of second countdown
setting
0 to 65535 1 0
☆
FA-03 Second countdown 0 to 65535 h 1 h 0
☆
FA-04 Password of third countdown setting 0 to 65535 1 0
☆
FA-05 Third countdown 0 to 65535 h 1 h 0
☆
FA-06 Password of forth countdown setting 0 to 65535 1 0
☆
FA-07 Forth countdown 0 to 65535 h 1 h 0
☆
FA-08 Business running time in total(hour) 0 to 65535 h 1 h 0 ●
FA-09 Business running time in
total(second)
0s to 3600s 1s 0 ●
Group FB Optimization
FB-04 Overcurrent prevention enable 0: Disable
1: enable
1 1
★
Group FC: Multi-point Calibration
FC-00 Multi-point AI calibration enable 0: no calibration
1: AI1 enable
2: AI2 enable
3: AI1 and AI2 enable
0 0
★
FC-01 Minimum AI1 input -11�00 to 11�00 V 0�01 V 0�02 V
☆
FC-02 Correspondent value of minimum
AI1 input
-100�0% to 100�0% 0�1% 0�0%
☆
FC-03 AI1 point 1 input -11�00 to 11�00 V 0�01 V 1�00 V
☆
FC-04 Correspondent value of AI1 point 1
input
-100�0% to 100�0% 0�1% 10�0%
☆
FC-05 AI1 point 2 input -11�00 to 11�00 V 0�01 V 2�00 V
☆
FC-06 Correspondent value of AI1 point 2
input
-100�0% to 100�0% 0�1% 20�0%
☆
FC-07 AI1 point 3 input -11�00 to 11�00 V 0�01 V 3�00 V
☆
FC-08 Correspondent value of AI1 point 3
input
-100�0% to 100�0% 0�1% 30�0%
☆
FC-09 AI1 point 4 input -11�00 to 11�00 V 0�01 V 4�00 V
☆