4 Quick Steup 
 
 
4
- 41 -
Continue Para. Parameter Name Default Commissioning
H04-07  DO4  function selection  11
11: ALM (Fault output)
H04-08  DO4 logic selection  0
H04-09  DO5 function selection  16
16: Home Attain (Home attaining output)
H04-10  DO5 logic selection  0
Set AO1 if used H04-50 AO1 signal selection 0
0: Motor speed
H04-51 AO1 offset voltage 5000
H04-52  AO1 multiplying factor 1
Set AO2 if used H04-53 AO2 signal selection 1
1: Speed reference
H04-54 AO2 offset voltage 5000
H04-55  AO2 multiplying factor 1
Set pulse output if used H05-38 Servo pulse output source 0 0 or 1 
0: Encoder frequency-division output 
1: Pulse synchronous output 
2: Frequency-division or synchronous output inhibited
H05-17 Encoder frequency-division pulses 2500 p/r 
35 to 32767 
H02-03  Output pulse phase 0
0: CCW direction as forward direction (phase A advancing phase 
B) 
1: CW direction as forward direction (phase A lagging phase B)
H05-41  Output polarity of Z pulse 0
0: Positive (high level when pulse Z is valid) 
1: Negative (low level when pulse Z is valid)
Over