Function
Code
Parameter Name
Setting Range
Unit
Default
Commission
F0-07
Frequency source
superposition
selection
7-segment
-
-
-
0
0
N.A. 00
0: X + Y
1: X – Y
2: Max. (X, Y)
3: Min. (X, Y)
0: Main frequency source X
1: X and Y superposition
2: Switchover between X and Y
(by DI terminal)
3: Switchover between X and
"X and Y superposition"(by DI
terminal)
4: Switchover between Y and
"X and Y superposition"(by DI
terminal)
F0-08
Preset frequency
0.00 to Max. frequency
Hz
50.00
X
Y
X &Y
Unit’s digit
F 0-07
Final frequency reference
Superposition
X &Y
Ten’s digit
F 0-07
The larger of X and Y
Max. (X, Y)
The smaller of X and Y
Min. (X, Y)
Difference between X and Y
X-Y
Sum of X and Y
X+Y
F 0-04
Auxiliary source
Main source
F 0-03
X
Y
Communication
Fx-xx
PID input
Fx-xx
Simple PLC
Fx-xx
Multi-frequency input
Fx-xx
Pulse input
Fx-xx
Analog input
Fx-xx
Digital input (retentive)
F0-08
Digital input (non-retentive)
F0-08
efesotomasyon.com