Function Parameter Table MD280/MD280N User Manual
- 104 -
Function code Name Setup Range
Minimu
m Unit
Factory
Default
Value
Change
points
selection
corresponding bus voltage of
350.0V.
Two phase ˖ 100.0%
corresponding bus voltage of
200.0V
FB-29
Zero
current
detectio
n level
0.0% to 300.0%
100.0%correspondingmmotro
rated current
0.1% 5.0% ƿ
FB-30
Zero
current
detectio
n delay
time
0.01s to 600.00s 0.01s 0.10s ƿ
Group FC The second motor parameters
FC-00
The
second
motorrat
ed
power
0.2Kw to 1000.0kW 0.1kw
Model
dependent
ƾ
FC-01
The
second
motor
rated
voltage
0V to 480V 1V
Model
dependent
ƾ
FC-02
The
second
motor
rated
current
0.1A to 6553.5A 0.1A
Model
dependent
ƾ
FC-03 The 0.01Hz to maximum frequency 0.01Hz Model ƾ