MD280/MD280N User Manual Parameter Description
- 173 -
MF.K key function
selection
Factory default
value
0
0 MF.K key function disabled
1
Switching between the operation panel
command channel and the remote
command channel (terminal command
channel or serial port command channel)
2
Switching between forward and reverse
rotations
F7-15
Setup
range
3 Forward jog command
It is used to set the functions of multifunctional MF.K key.
0: Disabled
1: Operation panel command channel and remote command channel:
When the command source (F0-00) is “terminal command channel” (or
“serial port communication control channel”), it can perform switching
between the “terminal command channel" (or “serial port communication
control channel”) and “operation panel command channel”.
2: Switching between forward and reverse rotation
Switching the rotary direction of the motor via the MF.K key on the
keyboard is only enabled when the command source (F0-00) is “operation
panel command”.
3: Forward jog
It can perform forward jog (FJOG) operation via the MF.K key on the
keyboard.
Caution:
1) The switching functions of the MF.K key (channel switching and
switching between forward rotation and reverse rotation) can be
performed in both the stop and running status.
2) If DI terminal sets the functions of “Keyboard Command Source
Switching” or “Terminal Command Source Switching” to be valid.
“Operation Panel Command Channel” and “Remote Command
Channel function” will be disabled.
STOP/RESET key
function
Factory
default value
0
0: The stop function of STOP/RES key is valid
only in the keyboard control mode.
F7-16
Setup
value
1: The stop function of STOP/RES key is valid
in any control mode.