Loading...
MD280/MD280N User Manual Function Parameter Table
- 73 -
Function code Name Setup Range
Minimu
m Unit
Factory
Default
Value
Change
F1-04
V/F
curve
setup
0: Linear V/F curve
1:Multiple-point V/Fcurve
2:Square V/F curve
1 0 ƾ
F1-05
Torque
hoist
0.0%˄auto˅ 0.1% to 30.0%
0.1%
Model
dependent
ƿ
F1-06
Torque
boost
cutoff
frequenc
y
0.00Hz to maximu frequency
˄F0-04˅
0.01Hz 50.00Hz ƾ
F1-07
Multi-poi
nt V/F
frequenc
y point
f1
0.00Hz to F1-09 0.01Hz 0.00Hz ƾ
F1-08
Multi-poi
nt V/F
frequenc
y point
v1
0.0% to 100.0% 0.1% 0.0% ƾ
F1-09
Multi-poi
nt V/F
frequenc
y point
f2
F1-07 to F1-11 0.01Hz 0.00Hz ƾ
F1-10
Multi-poi
nt V/F
voltage
point v2
0.0% to 100.0% 0.1% 0.0% ƾ
F1-11
Multi-poi
nt V/F
F1-09 to Motor rated frequency
(F1-03)
0.01Hz 0.00Hz ƾ