Function code Name Setup Range
Minimu
m Unit
Factory
Default
Value
Change
delay
time
F3-10
DO1
output
delay
time
0.0s to 3600.0s 0.1s 0.0s ƿ
F3-11
DO2
output
delay
time
0.0s to 3600.0s 0.1s 0.0s ƿ
F3-12
DO3
output
delay
time
0.0s to 3600.0s 0.1s 0.0s ƿ
F3-13
DO
output
terminal
valid
status
selection
0 to 15 1 0 ƿ
Group F4 Start/Stop Control
F4-00
Startup
mode
0: Direct startup
1:Rotation velocity tracking startup
1 0 ƾ
F4-01
Rotation
speed
tracking
mode
0:Start from stop frequency
1: Start from zero speed
2: Start from maximum frequency
1 0 ƿ
F4-02
Rotation
speed
tracking
fastness
1 to 100 1 20 ƿ