Function Parameter Table MD280/MD280N User Manual
- 92 -
Function code Name Setup Range
Minimu
m Unit
Factory
Default
Value
Change
F7-14
LED stop
display
parameter
1 to 511 1 51 ƿ
F7-15
MF.K key
function
selection
0: MF.K invalid
1: Switching between the
operation panel command
channel and the remote command
channel (terminal command
channel or serial port command
channel)
2: Switching between forward and
reverse rotation
3: Forward jog
1 0 ƾ
F7-16
STOP/RE
S key
function
0: The stop function of
STOP/RES key is valid only in the
keyboard control mode.
1: The stop function of STOP/RES
key is valid in any control mode.
1 0 ƿ
F7-17
Software
version
No.
0.01 to 655.35
ˉ ˉ
Ɣ
Group F8 MS speed and PLC
F8-00
MS
speed 0
referenc
e mode
0: F8-01 reference
1: AI1
2: AI2
3: pulse
4: PID
5:preset frequency ˄ F0-03 ˅
reference, UP/DOWN can be
changed
1 0 ƾ