6. Description of Parameters
- 165 -
6
U0-42: It displays DO state and the display format is shown as below:
VDO4
DO terminal state
ON: High level
OFF: Low level
VDO5
VDO2
VDO3
DO2
VDO1
Relay2
DO1
DO3
Relay1
Function Code Parameter Name Display Range
U0-43
DI set for function state display 1 -
U0-43: It displays whether DI terminals set for functions 1 to 40 are active. The operation panel
KDV¿YHVHJPHQW/('VDQGHDFKVHJPHQW/('GLVSOD\VVHOHFWLRQRIHLJKWIXQFWLRQV7KH
VHJPHQW/('LVGH¿QHGDVEHORZ
DI terminal function:
ON: Active
OFF: Inactive
4
1
2
6
53
7
8
Function Code Parameter Name Display Range
U0-44
DI set for function state display 2 -
U0-44: It displays whether DI terminals set for functions 41 to 59 are active. The display format is
similar to U0-43. The 7-segment LEDs display functions 41–48, 49–56 and 57–59, respectively
from right to left.
Function Code Parameter Name Display Range
U0-59
Frequency Reference -100.00% to 100.00%
U0-60
Running frequency -100.00% to 100.00%
Function Code Parameter Name Display Range
U0-61
AC drive state 0 to 65535
U0-61: It displays the drive state. The data format is listed in the following table:
Bit0 0: Stop
1: Forward
2: Reverse
Bit1
Bi2 0: Constant
1: Accelerate
2: Decelerate
Bit3
Bit4 0: Bus voltage normal
1: Undervoltage
Function Code Parameter Name Display Range
U0-62
Current fault code 0 to 99
U0-64
Number of slaves 0 to 63