Extension Mini I/O Card (MD38IO2)
0',2LVVLPSOL¿HGYHUVLRQRI0',2DQGSURYLGHVWKUHH',WHUPLQDOV
DI6 DI7 DI8
J2
COM OP2 +24V
CN1
CN2
Table 8-3 Terminal descriptions of the MD38IO2
Type Terminal Terminal Name Function Description
Power
supply
+24V-COM External +24V
power supply
Provide +24 V power supply to an external unit.
Generally used to supply DI/DO terminals and
external sensors.
Max. output current: 170 mA
OP2 Digital input
power terminal
It is not connected to power supply by default.
It can be connected either to external power or
+24V according to the actual need.
Digital
inputs
DI6-OP2 Digital input 6 Optically-coupled isolation compatible with dual-
polarity inputs
,QSXWUHVLVWDQFHNȍIRU',DQG',Nȍ
for DI8
Voltage range for inputs: 9 to 30 V
DI6, DI7 and DI8 are common input terminals
with input frequency < 100 Hz.
DI7-OP2 Digital input 7
DI8-OP2 Digital input 8
Table 8-4 Jumper descriptions of the MD38IO2
Jumper Description Meaning Setting
J2 OP2 connecting mode
selection
If DI connected in SINK mode, OP2
connected to +24V
If DI connected in SOURCE mode,
OP2 connected to COM
Note
Setting of jumpers takes top view with main terminals at the bottom of the