Appendix
- 317 -
12
Para. No. Para. Name Setting Range Default Property Page
F6-10 Stop mode 0: Decelerate to stop
1: Coast to stop
0
ƿ
1
3
9
F6-11 DC injection braking 2 start
frequency
0.00 Hz to maximum frequency 0.00 Hz
ƿ
1
3
9
F6-12 DC injection braking 2 delay
time
0.0 to 100.0s 0.0s
ƿ
1
3
9
F6-13 DC injection braking 2 level 0% to 100% 50%
ƿ
1
3
9
F6-14 DC injection braking 2 active
time
0.0s to 100.0s 0.0s
ƿ
1
3
9
F6-15 Braking use ratio 0% to 100% 100%
ƿ
-
F6-18 Catching a spinning motor
current limit
30% to 200% Model
dependent
ƾ
-
F6-21 Demagnetization time 0.00s to 5.00s Model
dependent
ƿ
-
Group F7: Keypad Operation and LED Display
F7-00 LED default display check
0: Disabled
1: Enabled
0
ƿ
-
F7-01 MF.K key function selection
0: MF.K key disabled
1: Switchover from remote control
(terminal or communication) to
keypad control
2: Switchover between forward
rotation and reverse rotation
3: Forward jog
4: Reverse jog
0
ƾ
-
F7-02 STOP/RESET key function
0: STOP/RESET key enabled only
in keypad control
1: STOP/RESET key enabled in
any operation mode
1
ƿ
-
F7-03
LED display running parameters 1
0000 to FFFF
7 6 5 4 3 2 1 0
Running frequency 1 (Hz)
Frequency reference (Hz)
Bus voltage (V)
Output voltage (V)
Output current (A)
Output power (kW)
Output torque (%)
DI state (V)
15 14 12 11 10 9 8
DO state
AI1 voltage (V)
Count value
Length value
Load speed display
PID reference
13
AI2 voltage (V)
AI3 voltage (V)
1F
ƿ
1
6
1

Table of Contents