Appendix
- 329 -
12
Para. No. Para. Name Setting Range Default Property Page
Group Fd: Communication
Fd-00 Baud rate 0000 to 6039
PROFIBUS-DP baud rate:
0: 115200 bps
1: 208300 bps
2: 256000 bps
3: 512000 bps
Modbus baud rate:
0: 300 bps
1: 600 bps
2: 1200 bps
3: 2400 bps
4: 4800 bps
5: 9600 bps
6: 19200 bps
7: 38400 bps
8: 57600 bps
9: 115200 bps
Initial position fault (Err51):
Same as that of units position
CANlink baud rate:
0: 20 Kbps
1: 50 Kbps
2: 100 Kbps
3: 125 Kbps
4: 250 Kbps
5: 500 Kbps
6: 1 Mbps
5005
ƿ
2
2
4
Fd-01 Data format symbol 0: No check: data format <8, N, 2>
1: Even parity check: data format
<8, E, 1>
2: Odd parity check: data format
<8, O, 1>
3: No check: data format <8, N, 1>
0
ƿ
2
2
5
Fd-02 Local address 0: Broadcast address;
1 to 247
1
ƿ
2
2
5
Fd-03 Response delay 0 to 20 ms 2
ƿ
2
2
5
Fd-04 Communication timeout 0.0s: invalid
0.1s to 60.0s
Valid for Modbus, PROFIBUS-DP
and CANlink
0.0s
ƿ
2
2
5
Fd-05 Modbus protocol selection and
PROFIBUS-DP data frame
00 to 31
PROFIBUS-DP data frame
0: PPO1 format
1: PPO2 format
2: PPO3 format
3: PPO5 format
Modbus protocol selection
0: Non-standard Modbus protocol
1: Standard Modbus protocol
30
ƿ
2
2
5
Fd-06 Current resolution read by
communication
$YDOLGZKHQN:
1: 0.1 A
0
ƿ
2
2
5
Fd-08 CANlink communication timeout
time
0.0s (invalid)
0.1s to 60.0s
0
ƿ
1
9
2