EasyManua.ls Logo

Inovance MD290 Series - Page 333

Inovance MD290 Series
350 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
- 332 -
12
Para. No. Para. Name Setting Range Default Property Page
A1-01 VDI2 function selection 16: Terminal 1 for acceleration/
deceleration time selection
17: Terminal 2 for acceleration/
deceleration time selection
18: Frequency reference setting
channel switchover
19: UP and DOWN setting clear
(terminal, operation panel)
20: Command source switchover 1
21: Acceleration/Deceleration
prohibited
22: PID disabled
23: PLC state reset
24: Wobble disabled
25: Counter input
26: Counter reset
27: Length signal pulses count
28: Length reset
30: Pulse input as frequency
reference (valid only for DI5)
31: Reserved
32: Immediate DC injection
braking
33: External fault normally-closed
input
)UHTXHQF\PRGL¿FDWLRQ
enabled
35: PID operation direction
reverse
36: External stop 1
37:
Command source switchover
2
38: PID integral disabled
39: Switchover between main
frequency reference and preset
frequency
40: Switchover between auxiliary
frequency reference and preset
frequency
41: Motor selection
42: Reserved
43: PID parameter switchover
8VHUGH¿QHGIDXOW
8VHUGH¿QHGIDXOW
47: Emergency stop (ES)
48: External stop 2
49: Deceleration DC injection
braking
50: Clear running time this time
51: Two-wire control/ Three-wire
control
52: Reverse running prohibited
53 to 59: Reserved
0
ƾ
1
8
6
A1-02 VDI3 function selection 0
ƾ
1
8
6
A1-03 VDI4 function selection 0
ƾ
1
8
6
A1-04 VDI5 function selection 0
ƾ
1
8
6

Table of Contents

Related product manuals