Appendix
- 334 -
12
Para. No. Para. Name Setting Range Default Property Page
A1-08 Function selection for AI2 used as
DI
20: Command source switchover 1
21: Acceleration/Deceleration
prohibited
22: PID disabled
23: PLC state reset
24: Wobble disabled
25: Counter input
26: Counter reset
27: Length signal pulses count
28: Length reset
30: Pulse input as frequency
reference (valid only for DI5)
31: Reserved
32: Immediate DC injection
braking
33: External fault normally-closed
input
)UHTXHQF\PRGL¿FDWLRQ
enabled
35: PID operation direction
reverse
36: External stop 1
37:
Command source switchover
2
38: PID integral disabled
39: Switchover between main
frequency reference and preset
frequency
40: Switchover between auxiliary
frequency reference and preset
frequency
41: Motor selection
42: Reserved
43: PID parameter switchover
8VHUGH¿QHGIDXOW
8VHUGH¿QHGIDXOW
47: Emergency stop (ES)
48: External stop 2
49: Deceleration DC injection
braking
50: Clear running time this time
51: Two-wire control/ Three-wire
control
52: Reverse running prohibited
53 to 59: Reserved
0
ƾ
1
8
9
A1-09 Function selection for AI3 used as
DI
0
ƾ
1
8
9